Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная Archive
02 | 05 | 2024
2020, 06 June

DOI: 10.14489/td.2020.06.pp.040-044

Bardakov V. V., Elizarov S. V., Barat V. A., Kharebov V. G., Medvedev K. A.
ACOUSTIC EMISSION TESTING OF POWER TRANSFORMERS INSULATION
(pp. 40-44)

Abstract. Testing results of power transformers insulation for the presence of insulation defects, accompanied by the partial discharges occurrence, by means of the acoustic emission method are presented in this article. In particular, the testing of two power transformers with different lifetime was carried out. One transformer was defect-free and one with a willing insulation defect. Based on the testing results, the features of acoustic emission data for power transformers in the presence of partial discharges are found. High sensitivity of acoustic emission method for acoustic wave registration from partial discharges is shown in the article.  A method for filtering of noise hits and extraction of hits from partial discharges is proposed. This method is based on excretion of acoustic emission hits from partial discharges out of total number of hits by means of periodicity of their registration, which is synchronized with power supply frequency on the first step. On the next step based on acoustic emission parameters of hits excretion on the previous step, filtration was carried out. The location of the insulation defect which led to the appearance of partial discharges was determined based on the volume location algorithm, by means of acoustic emission method. The insulation defect was confirmed by verification.

Keywords: acoustic emission, power transformers, partial discharges.

V. V. Bardakov, S. V. Elizarov, V. A. Barat (LLC “INTERUNIS-IT”, Moscow, Russia) E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра. , Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра. , Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.
V. G. Kharebov, K. A. Medvedev (LLC “Research and engineering center Aegis”, Moscow, Russia) E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра. , Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.

1. Rusov V. A. (2011). Partial discharge measurement in the isolation of high voltage equipment. Ekateriburg: UrGUPS. [in Russian language]
2. Karandaev A. S., Evdokimov S. A., Karandaeva O. I. et al. (2008). Technical condition testing of power transformers by acoustic detection. Vestnik YuUrGU, 26, pp. 26 – 31. [in Russian language]
3. Gun I. G., Salganik V. M., Evdokimov S. A. et al. (2012). Main faults and methods for diagnosing of power transformers in operating mode. Vestnik MGTU im G.I. Nosova, (1), pp. 102 – 105. [in Russian language]
4. Karandaev A. S., Evdokimov S. A., Devyatov D. H. et al. (2012). Diagnostics of power transformers by the method of acoustic location of partial discharges. Vestnik MGTU im G.I. Nosova, (1), pp. 105 – 108. [in Russian language]
5. Sikorski, W., Walczak K. (2012). Power Transformer Diagnostics Based on Acoustic Emission Method In Book Acoustic Emission. Research and Application, Chapter 5, pp. 91 – 116.
6. Bardakov V.V., Barat V.A., Terent'ev D.A. et al. (2016). Features of the AE method application in monitoring of bridge constructions. Kontrol'. Diagnostika, 211(1), pp. 32 – 39. [in Russian language] DOI: 10.14489/td.2016.01.pp.032-039

This article  is available in electronic format (PDF).

The cost of a single article is 350 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please copy the article doi:

10.14489/td.2020.06.pp.040-044

and fill out the  form  

 

 

 