Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная Archive
05 | 05 | 2024
2014, 02 February

DOI: 10.14489/TD.2014.02.PP.024-031 


Artem'ev B.V., Shubochkin A.E.

RESEARCH AND DEVELOPMENT OF X-RAY THICKNESS GAUGES, METHODS OF CONTROL AND MEASUREMENT ASSURANCE
(pp. 24-31)

Abstract. The article discusses the physical principles of X-ray thickness gauges for metals with an arbitrary value of the effective atomic number. The calculated and experimental measurement signal depends on the energy of the radiation, the thickness of the test object with a correction for the chemical composition of the material. Given a block diagram of the algorithm of the X-ray thickness gauge RIT10-6. Detail the process calibration. A system diagnostics and gather statistics about failures and faults integrated into the RT. An roll passport containing information about gage, date and time of release, the length of the roll, room and workshop teams to manufacture this car formed at the end of the process rolling.

Keywords: X-ray inspection, thickness measurement, X-ray thickness measurement.

 

 Artem'ev B.V., Shubochkin A.E. 
Closed Joint-Stock Company "Research Institute of Introscopy of MSIA "Spectrum", Moscow, Russia. E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.

 

 

1. Artem'ev B. V. (2002). X-ray thickness gauging of metals. Moscow: Mashinostroenie.
2. Artem'ev B. V., Maslov A. I. (2006). Opportunities of multielectrode heterogeneous ionization chambers for x-ray thickness gauging. Defektoskopiia, (5), pp. 80-86.
3. Artem'ev B. V. (2009). X-ray thickness gauges. Kontrol'. Diagnostika, (4), pp. 22-25.
4. Artem'ev B. V., Buklei A. A. (2011). X-ray inspection. Moscow: Izdatel'skii dom "Spektr".
5. Artem'ev B. V., Maslov A. I., Potapov V. N., Vedernikov M. B. (2003). Implementation of x-ray thickness gauges in the production of rolled non-ferrous metals. Defektoskopiia, (6), pp. 55-61.
6. Maslov A. I., Artem'ev B. V., Zapuskalov V. G. et al. (2004). X-ray measuring device for the parameters of the rolled metal alloy. Patent on Invention No. RUS 2257543. Russian Federation.
7. Artem'ev B. V., Egorov I. V., Zapuskalov V. G. et. al. (2000). X-ray thickness gauge. Patent on Invention No. RUS 2172930. Russian Federation.
8. Artem'ev B. V., Vedernikov B. G., Egorov I. V. et. al. (2000). X-ray thickness gauge. Patent on Invention No. RUS 2159408. Russian Federation.
9. Maslov A. I., Zapuskalov V. G., Egorov I. V. X-ray thickness gauge. Patent on Invention No. RUS 2189008. Russian Federation

 

 

This article  is available in electronic format (PDF).

The cost of a single article is 350 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please fill out the form below:

Purchase digital version of a single article


Type the characters you see in the picture below



 

 

 

 

 

 
Search
Баннер
Rambler's Top100 Яндекс цитирования