DOI: 10.14489/td.2014.08.pp.023-027
Firsov A.A., Terentyev D.А. Abstract. A band selection algorithm to improve the location accuracy of correlation leak detection at low signal-to-noise ratio is implemented. The algorithm involves the determination of the frequency range in which the phase of cross spectrum is a sawtooth function and the subsequent narrow band filtering of the acoustic signals. Approbation during the testing of the pipelines of the district heating systems was successful. Absolute deviation was equal to 2...3 m. Keywords: correlation leak detection, location accuracy, phase of cross spectrum, district heating systems.
A. A. Firsov, D. A. Terentyev
1. Borodin Iu. P., Kharebov V. G. (2003). Ways to improve the reliability of pipeline operations. Kontrol'. Diagnostika, (9), pp. 41-43.
This article is available in electronic format (PDF). DOI: 10.14489/td.2014.08.pp.023-027 Copy the article DOI and follow the link https://id-spektr.ru/product/pokupka-elektronnoy-stati-iz-zhurnala-kontrol-diagnostika Please specify the article DOI in the order comments.
|